Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Clinical Endoscopy ; : 558-563, 2022.
Article in English | WPRIM | ID: wpr-937357

ABSTRACT

Background/Aims@#Bispectral index (BIS) monitors process and display electroencephalographic data are used to assess the depth of anesthesia. This study retrospectively evaluated the usefulness of BIS monitoring during endoscopic ultrasonography (EUS). @*Methods@#This study included 725 consecutive patients who underwent EUS under sedation with propofol. BIS monitoring was used in 364 patients and was not used in 361. The following parameters were evaluated: (1) median dose of propofol; (2) respiratory and circulatory depression; (3) occurrence of body movements; (4) awakening score >8 at the time; and (5) awakening score 2 hours after leaving the endoscopy room. @*Results@#The BIS group received a significantly lower median dose of propofol than the non-BIS group (159.2 mg vs. 167.5 mg; p=0.015) in all age groups. For patients aged ≥75 years, the reduction in heart rate was significantly lower in the BIS group than in the non-BIS group (1.2% vs. 9.1%; p=0.023). Moreover, the occurrence of body movements was markedly lower in the BIS group than in the non-BIS group (8.5% vs. 39.4%; p<0.001). @*Conclusions@#During EUS examination, BIS monitoring is useful for maintaining a constant depth of anesthesia, especially in patients 75 years of age or older.

2.
Arab Journal of Gastroenterology. 2017; 18 (2): 120-121
in English | IMEMR | ID: emr-189177

ABSTRACT

EUS-guided hepaticogastrostomy [EUS-HGS] is useful for treating obstructive jaundice. However, stent migration may sometimes occur both during and after the procedure. This report describes a patient with pancreatic cancer and massive ascites who underwent EUS-HGS combined with EUS-guided antegrade stenting [EUS-AS], with additional EUS-AS playing a role in troubleshooting for stent migration during EUS-HGS


Subject(s)
Humans , Female , Aged , Gastrostomy , Stents , Prosthesis Failure , Endoscopy , Ultrasonography , Pancreatic Neoplasms , Tomography, X-Ray Computed
3.
Ultrasonography ; : 169-179, 2016.
Article in English | WPRIM | ID: wpr-731075

ABSTRACT

Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS. EUS-guided fine needle aspiration (EUS-FNA) has been used for diagnosing pancreatic tumors. In order to improve the histological diagnostic yield, a EUS-FNA needle with a core trap has recently been developed. Contrast-enhanced harmonic EUS is a new imaging modality that uses an ultrasonographic contrast agent to visualize blood flow in fine vessels. This technique is useful in the diagnosis of pancreatic solid lesions and in confirming the presence of vascularity in mural nodules for cystic lesions. EUS elastography analyzes several different variables to measure tissue elasticity, color patterns, and strain ratio, using analytical techniques such as hue-histogram analysis, and artificial neural networks, which are useful for the diagnosis of chronic pancreatitis and pancreatic cancer.


Subject(s)
Biliary Tract , Biopsy, Fine-Needle , Diagnosis , Diagnosis, Differential , Elasticity , Elasticity Imaging Techniques , Endoscopic Ultrasound-Guided Fine Needle Aspiration , Endosonography , Needles , Pancreas , Pancreatic Neoplasms , Pancreatitis, Chronic
SELECTION OF CITATIONS
SEARCH DETAIL